AN EXPERIMENTAL STUDY ON THE BOLTED JOINT CONNECTIONS IN GFRE [0/90jzs LAMINATES

Document Type : Original Article

Authors

Mechanical Design and Production Engineering Department, Faculty of Engineering Zagazig University, P.O. Box 44519, Zagazig, Egypt.

Abstract

Bolts provide the prima'y means of connecting composite parts in the construction of aircrafts and
aerospace vehicles. The objective of the present study is to determine the effect of bolt / hole
clearance and the cut-off angle on the failure load and mode of laminated Glass Fiber Reinforced
Epoxy laminates (GFRE) with 0.4 fiber volume fraction. Five clearance values were used. The
results showed that the specimen Failure Load decreased by increasing the clearance value and the
failure mode did not affected. Four cut of angles were tested. The results showed that the failure
load decreased as the cut-off angle increased up to 30 ' and then increased

Keywords