Induction motor operated with pole amplitude modulation technique is to give two speeds or more. The motor parameters are modified for each speed. These parameters are function of the motor number of poles, number of stator series turns per phase, stator winding factor and type of operation. The parameters of a tested motor are calculated taking into account the above factors at two speeds 1500 & 3000 r.p.m. The performance characteristics of the motor are calculated based on the equivalent circuit and compared with experimental results.
Abdel-kader, F., Abou Mobarka, A., & Abouel-fadi, W. (2000). Performance Analysis of Pole Amplitude Modulation Motors. ERJ. Engineering Research Journal, 23(2), 231-246. doi: 10.21608/erjm.2000.71348
MLA
F.E. Abdel-kader; A.E. Abou Mobarka; W.S. Abouel-fadi. "Performance Analysis of Pole Amplitude Modulation Motors". ERJ. Engineering Research Journal, 23, 2, 2000, 231-246. doi: 10.21608/erjm.2000.71348
HARVARD
Abdel-kader, F., Abou Mobarka, A., Abouel-fadi, W. (2000). 'Performance Analysis of Pole Amplitude Modulation Motors', ERJ. Engineering Research Journal, 23(2), pp. 231-246. doi: 10.21608/erjm.2000.71348
VANCOUVER
Abdel-kader, F., Abou Mobarka, A., Abouel-fadi, W. Performance Analysis of Pole Amplitude Modulation Motors. ERJ. Engineering Research Journal, 2000; 23(2): 231-246. doi: 10.21608/erjm.2000.71348